Electrical Power Plant
Electrical Power Plant
Power Plant is an industrial facility used for generating electric power from primary energy sources such as hydro, thermal, or wind energy.
1. Theoretical Power of a Water Turbine
- Hydraulic Head: vertical distance water falls from reservoir to turbine (\(h\))
- Discharge Rate: volume rate of water flow passing through turbine (\(Q\))
- Specific Weight: weight of water per unit volume (\(w = 9810\ \text{N/m}^3\))
Theoretical Power of Water Turbine
Where: \(P\) = theoretical power (W), \(\text{Hp}_w\) = theoretical output horsepower (hp), \(Q\) = discharge flow rate (\(\text{m}^3/\text{s}\) or \(\text{ft}^3/\text{s}\)), \(w\) = specific weight of water (\(9810\ \text{N/m}^3\); \(62.4\ \text{lbs/ft}^3\)), \(h\) = head of water (\(\text{m}\); \(\text{ft}\)), \(k\) = unit conversion factor
Conversion Constants Table
| Discharge (\(Q\)) | Specific Weight (\(w\)) | Head (\(h\)) | Conversion Constant (\(k\)) |
|---|---|---|---|
| \(\text{ft}^3/\text{sec}\) | \(62.4\ \text{lbs/ft}^3\) | \(\text{feet}\) | \(550\) |
| \(\text{ft}^3/\text{min}\) | \(62.4\ \text{lbs/ft}^3\) | \(\text{feet}\) | \(33000\) |
| \(\text{m}^3/\text{sec}\) | \(9810\ \text{N/m}^3\) | \(\text{meter}\) | \(746\) |
| \(\text{m}^3/\text{min}\) | \(9810\ \text{N/m}^3\) | \(\text{meter}\) | \(44760\) |
EE Board Exam April 1994
Example. A waterfall is \(60\ \text{m}\) high and discharges at a rate of \(1.0\ \text{m}^3/\text{sec}\). A mini-hydroelectric plant below the waterfall has a turbine efficiency of \(80\%\) and a generator efficiency of \(95\%\). Calculate the kW output of the generator.
Solution.
Answer: \(447.34\ \text{kW}\)
2. Specific Speed of a Water Turbine
- Definition: speed of a turbine generating one horsepower under a one-foot head
- Design Parameter: dimensionless classification parameter used for turbine runner selection
Specific Speed and Actual Speed Equations
Where: \(N_s\) = specific speed (\(\text{rpm}\)), \(N\) = actual rotational speed (\(\text{rpm}\)), \(h\) = head of water (\(\text{foot}\)), \(\text{Hp}_w\) = theoretical horsepower of water turbine (\(\text{hp}\))
Example. A water turbine operating at \(85\%\) efficiency operates under a head of \(100\ \text{m}\) with a constant discharge of \(1000\ \text{gal/sec}\). Evaluate the operating speed of the turbine.
Solution.
Answer: \(654\ \text{rpm}\)
3. Turbine-Generator Setup
- Mechanical Coupling: water turbine shaft directly drives electric generator rotor
- Cascaded Efficiency: overall plant efficiency equals product of component efficiencies
Turbine-Generator Set Overall Efficiency
Where: \(\eta_{\text{overall}}\) = combined efficiency, \(\eta_t\) = turbine efficiency, \(\eta_g\) = generator efficiency, \(P_{\text{out}}\) = generator output power (W), \(\text{Hp}_w\) = theoretical water input horsepower (hp)
EE Board Exam October 1983 / EE Board Exam October 1990
Example. A waterfall \(50\ \text{m}\) high discharges \(1.3\ \text{m}^3/\text{sec}\). Calculate the annual energy in kW-hr generated by a plant at the bottom if turbine efficiency is \(70\%\) and generator efficiency is \(90\%\).
Solution.
Answer: \(3519067\ \text{kW-hr}\)
4. Heat Energy Conversion Factors
- Calorie to Joule: \(1\ \text{calorie} = 4.186\ \text{joules}\)
- BTU to Calorie: \(1\ \text{BTU} = 252\ \text{calories}\)
- Kilowatt-Hour to Joule: \(1\ \text{kW-hr} = 3.6 \times 10^6\ \text{joules}\)
- Heating Value: heat liberated per unit mass of burned fuel (\(\text{BTU/lb}\) or \(\text{kcal/kg}\))
Heat-to-Electrical Energy Conversion
Where: \(\text{J}\) = joules (SI unit), \(\text{cal}\) = calories, \(\text{BTU}\) = British Thermal Units (FPS unit), \(\text{kW-hr}\) = kilowatt-hours
EE Board Exam October 1997
Example. A power plant consumes \(100000\ \text{lbs}\) of coal per hour. The heating value of coal is \(12000\ \text{BTU/lb}\) and overall plant efficiency is \(30\%\). What is the kW output of the plant?
Solution.
Answer: \(105500\ \text{kW}\)
5. Terms Used in Prediction of Load
- Average Load (\(\text{AL}\)): mean load during a specified period (24 hours, month, or year)
- Peak Load (\(\text{PL}\)): maximum load demand registered during the period
- Connected Load (\(\text{CL}\)): sum of continuous ratings of all equipment connected
- Installed Capacity: total rated capacity of generating units in plant
Average Load Equations
Where: \(\text{AL}\) = average load (\(\text{kW}\)), \(\text{Annual energy}\) = total yearly energy output (\(\text{kW-hr}\))
Load, Demand, and Diversity Factors
Where: \(\text{LF}\) = load factor (\(\le 1.0\)), \(\text{DF}\) = demand factor (\(\le 1.0\)), \(\text{dF}\) = diversity factor (\(\ge 1.0\)), \(\text{AL}\) = average load (\(\text{kW}\)), \(\text{PL}\) = peak load (\(\text{kW}\)), \(\text{CL}\) = connected load (\(\text{kW}\))
Plant Capacity Factor and Plant Use Factor
Where: \(\text{PCF}\) = plant capacity factor, \(\text{PUF}\) = plant use factor, \(N\) = actual operating hours in one year
EE Board Exam October 1990
Example. A \(55000\ \text{kW}\) thermal power plant delivers an annual output of \(238000000\ \text{kW-hr}\) with a peak load of \(44\ \text{MW}\). Calculate the plant capacity factor.
Solution.
Answer: \(49.4\%\)
6. Formula Summary
| Formula Name | Formula | Variables |
|---|---|---|
| Theoretical Water Turbine Power | \(P = Q w h\) | \(P\) = power (\(\text{W}\)) \(Q\) = flow rate (\(\text{m}^3/\text{s}\)) \(w = 9810\ \text{N/m}^3\) \(h\) = head (\(\text{m}\)) |
| Theoretical Water Horsepower | \(\text{Hp}_w = \dfrac{Q w h}{k}\) | \(\text{Hp}_w\) = horsepower (\(\text{hp}\)) \(k\) = conversion constant |
| Specific Speed of Water Turbine | \(N_s = \dfrac{5050}{h + 32} + 19\) | \(N_s\) = specific speed (\(\text{rpm}\)) \(h\) = head (\(\text{ft}\)) |
| Actual Turbine Operating Speed | \(N = \dfrac{N_s h^{1.25}}{\sqrt{\text{Hp}_w}}\) | \(N\) = actual speed (\(\text{rpm}\)) \(N_s\) = specific speed (\(\text{rpm}\)) \(h\) = head (\(\text{ft}\)) \(\text{Hp}_w\) = water hp |
| Overall Hydroelectric Efficiency | \(\eta_{\text{overall}} = \eta_t \times \eta_g\) | \(\eta_{\text{overall}}\) = plant efficiency \(\eta_t\) = turbine efficiency \(\eta_g\) = generator efficiency |
| Daily Average Load | \(\text{AL}_{\text{day}} = \dfrac{\sum \text{demand of day}}{24}\) | \(\text{AL}_{\text{day}}\) = average daily load (\(\text{kW}\)) |
| Annual Average Load | \(\text{AL}_{\text{year}} = \dfrac{\text{Annual energy in kW-hr}}{8760}\) | \(\text{AL}_{\text{year}}\) = average yearly load (\(\text{kW}\)) |
| Load Factor | \(\text{LF} = \dfrac{\text{AL}}{\text{PL}}\) | \(\text{LF}\) = load factor \(\text{AL}\) = average load (\(\text{kW}\)) \(\text{PL}\) = peak load (\(\text{kW}\)) |
| Demand Factor | \(\text{DF} = \dfrac{\text{PL}}{\text{CL}}\) | \(\text{DF}\) = demand factor \(\text{PL}\) = peak load (\(\text{kW}\)) \(\text{CL}\) = connected load (\(\text{kW}\)) |
| Diversity Factor | \(\text{dF} = \dfrac{\sum \text{PL}_{\text{individual}}}{\text{PL}_{\text{station}}}\) | \(\text{dF}\) = diversity factor \(\text{PL}\) = peak load (\(\text{kW}\)) |
| Utilization Factor | \(\text{UF} = \dfrac{\text{PL}_{\text{station}}}{\text{Installed capacity}}\) | \(\text{UF}\) = utilization factor \(\text{PL}_{\text{station}}\) = station peak load (\(\text{kW}\)) |
| Plant Capacity Factor | \(\text{PCF} = \dfrac{\text{Annual energy in kW-hr}}{\text{Installed capacity in kW} \times 8760}\) | \(\text{PCF}\) = plant capacity factor |
| Plant Use Factor | \(\text{PUF} = \dfrac{\text{Annual energy in kW-hr}}{\text{Installed capacity in kW} \times N}\) | \(\text{PUF}\) = plant use factor \(N\) = annual operating hours |