Electrical Engineering · Question Bank

3P AC Circuits

23 of 71 questions match · page 1 of 2. Answer in your head first, then check the solution.

✕ Clear filters
#1📜 EE Pre-Board August 2012📘 PowerhouseEasy
A balanced delta connected load of (4 + j3) ohms per phase, 230 V supply. Find the total kVA.
A19.04 kVA
B37.01 kVA
C31.74 kVA
D25.39 kVA
#2📜 EE Pre-Board August 2013📘 PowerhouseEasy
A 230 V, 3-phase source supplies a balanced delta connected load of 8 − j6 Ω per phase. Find the line current in amperes.
A33.1
B39.8
C26.5
D29.3
#3📜 EE Pre-Board August 2013📘 PowerhouseEasy
A 220 v, 3-phase supply has a balanced delta connected load with impedance of 15 + j20 ohms/phase. What is the total real power of the load in watts?
A5,133.3
B4,122.5
C2,965.6
D3,484.8
#4📜 EE Pre-Board March 2014📘 PowerhouseEasy
A 240 v balanced 3ɸ source supplies a purely resistive impedance of 11.52 ohms per phase. What is the total power drawn if it is Y-connected?
A5 kW
B15 kW
C20 kW
D30 kW
#5📜 EE Pre-Board March 2014📘 PowerhouseEasy
A balanced delta connected load impedance of 15 + j18 Ω per phase is connected across a 230 v, three-phase source. Find the total power consumed.
A10,580 W
B1,445 W
C4,336 W
D3,527 W
#6📜 EE Pre-Board March 2014📘 PowerhouseEasy
A balanced wye – connected load with resistance of 8 ohms per phase and no reactance is supplied by a 240 v, 3 – phase source. Find the real power of the load in watts.
A6,400
B7,200
C6,800
D7,600
#7📜 EE Pre-Board August 2015📘 PowerhouseEasy
Three 40 Ω non-inductive resistances are connected in wye across 200 V, 3-phase lines. If one of the resistors is disconnected, what would be the power taken from the mains?
A3,000 W
B2,000 W
C1,000 W
D500 W
#8📜 EE Pre-Board August 2015📘 PowerhouseEasy
A 220 V, 3-phase supply has a balanced delta connected load with impedance of 15 + j20 Ω/phase. What is the total real power of the load in watts?
A5,133.3
B2,965.6
C4,122.5
D3,484.8
#9📜 EE Pre-Board August 2015📘 PowerhouseEasy
A balanced wye-connected load with resistance of 8 Ω/phase and no reactance is supplied by a 240v, 3-phase source. Find the real power of the load in watts.
A6,400
B7,200
C6,800
D7,600
#10📜 EE Pre-Board March 2016📘 PowerhouseEasy
A balanced delta load of 3+j4 ohms per phase is connected to a balanced 110v source. Find the line current.
A22A
B38.1A
C11A
D19.05A
#11📜 EE Pre-Board March 2016📘 PowerhouseEasy
A delta 3Φ, 4-wire secondary 230/115 V would have a high-leg to neutral voltage of ________.
A208 V
B230 V
C277 V
D199 V
#12📜 EE Pre-Board March 2017📘 PowerhouseEasy
Convert the delta connected impedance of \(12\angle 36^\circ\) Ω to a balanced wye connected impedance.
A\(3\angle 36^\circ\) Ω
B\(6\angle 36^\circ\) Ω
C\(4\angle 36^\circ\) Ω
D\(12\angle 36^\circ\) Ω
#13📜 EE Pre-Board March 2017📘 PowerhouseEasy
In a balanced 3-phase voltage source with phase sequence abc, the phase A voltage is \(127\angle 0^\circ\) volts. Find the phase C voltage.
A\(127\angle -240^\circ\) V
B\(220\angle -150^\circ\) V
C\(220\angle -120^\circ\) V
D\(127\angle -60^\circ\) V
#14📜 EE Pre-Board March 2017📘 PowerhouseEasy
A balanced delta connected load draws 10 A of line current and 3 KW at 220 v. Determine the value of resistance of each phase of the load.
A38.1 Ω
B30 Ω
C23.5 Ω
D33.3 Ω
#15📜 EE Pre-Board August 2017📘 PowerhouseEasy
A 440 V, three-phase source supplies a wye connected 10 kVA load at 0.8 lagging power factor and a delta-connected 10 kVA unity power factor load. Calculate the total apparent power input to the two loads.
A20 kVA
B18 kVA
C14.14 kVA
D18.97 kVA
#16📜 EE Pre-Board August 2017📘 PowerhouseEasy
A balanced wye-connected load with a resistance of 8 ohms/phase and no reactance is supplied by a 240 V, 3-phase source. Find the real power of the load in watts.
A2,400
B7,200
C21,600
D4,157
#17📜 EE Pre-Board August 2017📘 PowerhouseEasy
An abc phase sequence three-phase voltage source connected in a balanced wye has a line voltage of \(V_{ab} = 208\angle 0^\circ\) V rms. Determine the phase voltage \(V_{bn}\).
A\(120\angle -30^\circ\) V
B\(208\angle -120^\circ\) V
C\(120\angle -150^\circ\) V
D\(120\angle 90^\circ\) V
#18📜 EE Pre-Board August 2017📘 PowerhouseEasy
A balanced delta connected load of 4 − j3 Ω per phase is fed by a 380 V, 3-phase system. Find the reactive power.
A52 kVAR
B17.3 kVAR
C69.3 kVAR
D30 kVAR
#19📜 EE Pre-Board March 2018📘 PowerhouseEasy
In a delta connected circuit of three equal resistors, when one resistor is open, the power will be
A0
Bincreased by a factor of 3
Cdecreased by a factor of 3
Dremain unchanged
#20📜 EE Pre-Board March 2018📘 PowerhouseEasy
Three 100 μF capacitors are connected in delta to a 500-volt, three-phase, 50 Hz supply. Find the line current.
A15.71 A
B27.21 A
C31.83 A
D8.66 A

More Electrical Engineering topics