A 220 V, 3-phase supply has a balanced delta connected load with impedance of 15 + j20 Ω/phase. What is the total real power of the load in watts?
A5,133.3
B2,965.6
C4,122.5
D3,484.8
#22📜 EE Pre-Board August 2015📘 PowerhouseMedium
A delta connected load of 9 + j12 Ω/phase is supplied by a 230 V, 3-phase source through a line with an impedance of 0.06 + j0.12 Ω/conductor. Find the load voltage in volts.
A220
B222
C224
D226
#23📜 EE Pre-Board August 2015📘 PowerhouseEasy
A balanced wye-connected load with resistance of 8 Ω/phase and no reactance is supplied by a 240v, 3-phase source. Find the real power of the load in watts.
A6,400
B7,200
C6,800
D7,600
#24📜 EE Pre-Board March 2016📘 PowerhouseEasy
A balanced delta load of 3+j4 ohms per phase is connected to a balanced 110v source. Find the line current.
A22A
B38.1A
C11A
D19.05A
#25📜 EE Pre-Board March 2016📘 PowerhouseMedium
Three identical resistors are connected in wye across 220 v, 3-phase lines. The line current is12.7 A. To what value in volts should the line voltage be changed the same line current with the resistors connected in delta?
A98.6
B132.8
C120
D73.3
#26📜 EE Pre-Board March 2016📘 PowerhouseEasy
A delta 3Φ, 4-wire secondary 230/115 V would have a high-leg to neutral voltage of ________.
A208 V
B230 V
C277 V
D199 V
#27📜 EE Pre-Board March 2017📘 PowerhouseEasy
Convert the delta connected impedance of \(12\angle 36^\circ\) Ω to a balanced wye connected impedance.
A\(3\angle 36^\circ\) Ω
B\(6\angle 36^\circ\) Ω
C\(4\angle 36^\circ\) Ω
D\(12\angle 36^\circ\) Ω
#28📜 EE Pre-Board March 2017📘 PowerhouseEasy
In a balanced 3-phase voltage source with phase sequence abc, the phase A voltage is \(127\angle 0^\circ\) volts. Find the phase C voltage.
A\(127\angle -240^\circ\) V
B\(220\angle -150^\circ\) V
C\(220\angle -120^\circ\) V
D\(127\angle -60^\circ\) V
#29📜 EE Pre-Board March 2017📘 PowerhouseMedium
A 220 V, 3-phase, 4-wire abc system supplies unbalanced wye-connected resistances of 10 Ω, 15 Ω, and 20 Ω. Determine the total power of the system in watts.
A3,895
B3,560
C3,385
D3,495
#30📜 EE Pre-Board March 2017📘 PowerhouseEasy
A balanced delta connected load draws 10 A of line current and 3 KW at 220 v. Determine the value of resistance of each phase of the load.
A38.1 Ω
B30 Ω
C23.5 Ω
D33.3 Ω
#31📜 EE Pre-Board August 2017📘 PowerhouseEasy
A 440 V, three-phase source supplies a wye connected 10 kVA load at 0.8 lagging power factor and a delta-connected 10 kVA unity power factor load. Calculate the total apparent power input to the two loads.
A20 kVA
B18 kVA
C14.14 kVA
D18.97 kVA
#32📜 EE Pre-Board August 2017📘 PowerhouseEasy
A balanced wye-connected load with a resistance of 8 ohms/phase and no reactance is supplied by a 240 V, 3-phase source. Find the real power of the load in watts.
A2,400
B7,200
C21,600
D4,157
#33📜 EE Pre-Board August 2017📘 PowerhouseEasy
An abc phase sequence three-phase voltage source connected in a balanced wye has a line voltage of \(V_{ab} = 208\angle 0^\circ\) V rms. Determine the phase voltage \(V_{bn}\).
A\(120\angle -30^\circ\) V
B\(208\angle -120^\circ\) V
C\(120\angle -150^\circ\) V
D\(120\angle 90^\circ\) V
#34📜 EE Pre-Board August 2017📘 PowerhouseEasy
A balanced delta connected load of 4 − j3 Ω per phase is fed by a 380 V, 3-phase system. Find the reactive power.
A52 kVAR
B17.3 kVAR
C69.3 kVAR
D30 kVAR
#35📜 EE Pre-Board March 2018📘 PowerhouseEasy
In a delta connected circuit of three equal resistors, when one resistor is open, the power will be
A0
Bincreased by a factor of 3
Cdecreased by a factor of 3
Dremain unchanged
#36📜 EE Pre-Board March 2018📘 PowerhouseEasy
Three 100 μF capacitors are connected in delta to a 500-volt, three-phase, 50 Hz supply. Find the line current.
A15.71 A
B27.21 A
C31.83 A
D8.66 A
#37📜 EE Pre-Board March 2018📘 PowerhouseEasy
A balanced delta connected load consists of \(20\angle 25^\circ\) Ω impedances. The 60 Hz line voltage is 208 V. What is the line current?
A6A
B10.4A
C12A
D18A
#38📜 EE Pre-Board March 2018📘 PowerhouseEasy
A 230 v, 3-phase source supplies a balanced delta connected load with impedance of 8-j6 ohms per phase. Calculate the line current in amperes.
A33.1
B39.8
C26.5
D29.3
#39📜 EE Pre-Board March 2018📘 PowerhouseEasy
In a balanced 3-phase wye-connected voltage source with phase sequence abc, \(V_{ab} = 230\angle 10^\circ\) V. Find the phase voltage \(V_{cn}\).
A\(230\angle -230^\circ\) V
B\(132.8\angle -80^\circ\) V
C\(132.8\angle -140^\circ\) V
D\(132.8\angle -260^\circ\) V
#40📜 EE Pre-Board March 2018📘 PowerhouseMedium
A 480-V rms line feeds two balanced three-phase loads. If the two loads are rated as follows, Load 1: 5 kVA at 0.8 p.f. lagging Load 2: 10 kVA at 0.9 p.f. lagging Determine the magnitude of the line current from the 480-V rms source.