A dc machine has 8 poles and a rated current of 100A. How much current will flow in each conductor at rated condition if the armature is simplex lap wound?
A6.25A
B50A
C25A
D12.5A
#63📜 EE Pre-Board August 2014📘 PowerhouseEasy
Shunt generators are used where the main requirement is constant
Acurrent and voltage
Bcurrent
Cvoltage over a narrow load range
Dvoltage over a wide load range
#64📜 EE Pre-Board August 2014📘 PowerhouseEasy
A 4-pole lap-wound armature has 480 conductors and a flux per pole of 25mWb. What is the emf generated, when running at 600 rpm?
A240V
B120V
C60V
D30V
#65📜 EE Pre-Board August 2014📘 PowerhouseEasy
What is the nature of the current flowing in the armature of dc machine?
Apulsating dc
Bpure dc
Crectified ac
Dalternating current
#66📜 EE Pre-Board March 2015📘 PowerhouseEasy
The current flowing in the armature conductors of a dc motor is
Aac
Bdc
Cac as well as dc
Dtransients
#67📜 EE Pre-Board March 2015📘 PowerhouseMedium
A 10 kW, 110 volts dc series generator has a 2 volts brush drop, an armature resistance \(R_a\) of 0.1 Ω and a series field resistance \(R_s\) of 0.05 Ω. Calculate the generated emf when delivering rated current at rated speed.
A110 v
B130.25 v
C115.56 v
D125.64 v
#68📜 EE Pre-Board March 2015📘 PowerhouseEasy
Lap winding is best siuited for voltage, current dc generators.
AHigh, Low
BLow, High
CHigh, High
DLow, Low
#69📜 EE Pre-Board March 2015📘 PowerhouseMedium
The field current of a 200 kW, 230 volts shunt generator is 8 A when running full-load at rated terminal voltage. If the combined brush and armature resistance is 0.03 Ω, solve for the electrical efficiency of the generator.
A88.9%
B85.7%
C93.5%
D81.7%
#70📜 EE Pre-Board March 2015📘 PowerhouseEasy
The dc armature winding in which the coil sides are placed a pole pitch apart is called winding.
AMultiplex
BFull-pitch
CFractional-pitch
DPole-pitch
#71📜 EE Pre-Board August 2015📘 PowerhouseEasy
In a 12-Pole duplex lap wound dc armature, each conductor can carry a current of 50 amperes. If the total armature conductor is 600, what is the rated current of the armature?
A30,000 A
B1,200 A
C600 A
D2,500 A
#72📜 EE Pre-Board March 2016📘 PowerhouseEasy
A 4 pole dc generator has a total of 600 conductors in its lap wound armature. The flux per pole is \(10^{6}\) lines. Determine the generated emf if it is driven at 2400 rpm.
A230v
B254v
C234v
D240v
#73📜 EE Pre-Board March 2016📘 PowerhouseEasy
Once residual magnetism of a shunt generator is lost, it may be restored by connecting its shunt field.
Ato earth
Bin reverse
Cto an external battery
Dto an alternator
#74📜 EE Pre-Board March 2017📘 PowerhouseMedium
A 6-pole lap wound dc generator has 240 armature conductors, a flux of 0.04 Wb per pole and runs at 1,500 rpm. If the armature resistance is 0.8 Ω, determine the current through each conductor.
A300 A
B100 A
C50 A
D25 A
#75📜 EE Pre-Board March 2017📘 PowerhouseMedium
In a 4-pole dynamo, the flux per pole is 15 mWb. Calculate the maximum emf induced in one of the armature conductors if armature is driven at 600 rpm.
A0.6 v
B0.3 v
C0.94 v
D0.47 v
#76📜 EE Pre-Board March 2017📘 PowerhouseEasy
With reference to armature windings, wave windings are often called __________ windings.
Acascade
Bring
Cmultiple or parallel
Dseries
#77📜 EE Pre-Board March 2017📘 PowerhouseEasy
The active length of each conductor placed in a DC generator armature is 0.4 m. The armature is rotated at a speed of 1,800 rpm in a magnetic field of average flux density 1.2 T. The diameter of the armature is 0.5 m. Find the emf induced in the conductor when it cuts the magnetic field at right angles.
A5.65 v
B11.31 v
C45.24 v
D22.62 v
#78📜 EE Pre-Board March 2017📘 PowerhouseEasy
The purpose of providing dummy coils in a generator is
Ato reduce eddy current losses
Bto enhance flux density
Cto amplify voltage
Dto provide mechanical balance for the rotor
#79📜 EE Pre-Board August 2017📘 PowerhouseEasy
In a generator, if the voltage regulation is 5.5% and the full-load voltage is 220 volts, what is the no-load voltage?
A232.1 V
B207.9 V
C225.5 V
D241.2 V
#80📜 EE Pre-Board August 2017📘 PowerhouseEasy
A 4-pole wave wound generator has 220 coils of 10 turns each. The resistance of each turn is 0.02 Ω. Find the resistance of the armature winding.