A galvanometer with a 20 ohms coil resistance has a full scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rated capacity. What is the new full scale current for the meter?
A100.1 A
B1.01 A
C10.10 A
D10.01 A
#2📜 EE Pre-Board March 2015📘 PowerhouseEasy
A 200:5 current transformer is used with a 10 amps ammeter. If the meter reads 4.5 amps, determine the line current.
A400 A
B20 A
C45 A
D180 A
#3📜 EE Pre-Board March 2015📘 PowerhouseEasy
A dc ammeter has an internal resistance of 0.1 ohm. A shunt of \(1.01 \times 10^{-3}\) ohm is connected to the ammeter. What is the multiplier of the set up?
A80
B50
C100
D10
#4📜 EE Pre-Board August 2015📘 PowerhouseEasy
The input power to a 3-phase induction motor running without load is measured by the two wattmeter method. One wattmeter indicates −220 watts and the other indicates 940 watts. What is the no-load power factor of the motor?
A0.483
B0.253
C0.425
D0.337
#5📜 EE Pre-Board March 2016📘 PowerhouseEasy
A sinusoidal current having peak value 7.07 A is superimposed on dc of 5 A. If a hot-wire ammeter is used to measure the combined current in the circuit, it will indicate ___ amperes.
A7.07
B10
C12.07
D2.07
#6📜 EE Pre-Board March 2016📘 PowerhouseEasy
A meter has a full-scale current of 50 μA. What is its sensitivity?
A20 kΩ/V
B20 V/kΩ
C50 kΩ/V
D50 μA/V
#7📜 EE Pre-Board March 2016📘 PowerhouseEasy
Power in balance 3-phase system is measured by the two-wattmeter method and it is found that the ratio of the two-wattmeter readings is 2 is to 1. What is the power factor of the system?
A0.9
B0.82
C0.866
D0.707
#8📜 EE Pre-Board March 2017📘 PowerhouseEasy
What is the total power consumed by the load when the readings of two wattmeters are 5 kW and -0.5kW?
A5.5 kW
B4.5 kW
C5 kW
D4.05 kW
#9📜 EE Pre-Board March 2017📘 PowerhouseEasy
Given a 100 kVA 2,400/240 v single phase transformer. Find the current transformer (CT) ratio at the low voltage side.
A700:5
B600:5
C500:5
D400:5
#10📜 EE Pre-Board March 2017📘 PowerhouseEasy
A moving coil instrument requires 50 mA and 100 mV for full-scale deflection. What is the value of the shunt required to convert it to read up to 5 A?
A0.0101 Ω
B0.0202 Ω
C0.0303 Ω
D0.0404 Ω
#11📜 EE Pre-Board August 2017📘 PowerhouseEasy
A dc ammeter has an internal resistance of 0.1 Ω. A shunt of \(1.01 \times 10^{-3}\) Ω is connected to the ammeter. What is the multiplier of the set up?
A10
B50
C100
D99
#12📜 EE Pre-Board March 2018📘 PowerhouseEasy
The ratio of the wattmeter readings in three-phase inductive system is 2:1 when power is measured by the two-wattmeter method. What is the power factor of the load?
A0.5
B0.866
C0.75
D0.9
#13📜 EE Pre-Board August 2018📘 PowerhouseEasy
At a 115 kV substation, the PT ratio is 1,000 and the CT ratio is 1200/5. The potential going into the wattmeter is 115 volts. What is the MW indicated when the wattmeter reads 800 watts?
A150 MW
B192 MW
C15 MW
D19.2 MW
#14📜 EE Pre-Board August 2018📘 PowerhouseEasy
A dc ammeter has an internal resistance of 0.1 Ω. A shunt of \(1.01 \times 10^{-3}\) Ω is connected to the ammeter. What is the multiplier of the set up?
A10
B50
C80
D100