Problem 571: What is the speed of a 100 kW, 230-volt, three-phase, four-pole, 60 Hz alternator?
A450 rpm
B900 rpm
C1200 rpm
D1800 rpm
#2📜 EE Board April 1997📘 1001 RojasEasy
Problem 572: A six-pole, 3-phase AC generator has 72 slots, the coil span is 12. What is the pitch factor?
A1.000
B0.939
C0.985
D0.966
#3📘 1001 RojasEasy
Problem 578: A three-phase, 6-pole, 72-slot armature of a synchronous generator is wound using a two-layer lap coil having 20 conductors per coil with a pitch of 83.33%. The flux per pole is 4,800,000 maxwells. If the rotor of the generator is driven at a speed of 1200 rpm, calculate the induced emf per phase.
A5,680 V
B5,390 V
C5,564 V
D5,854 V
#4📜 EE Pre-Board August 2012📘 PowerhouseEasy
Calculate the average voltage generated in a six turn full pitch coil of a 60 cycle alternator if the flux per pole is \(7.2 \times 10^{5}\) maxwells.
A4.32 V
B23.4 V
C17.30 V
D10.37 V
#5📜 EE Pre-Board March 2013📘 PowerhouseEasy
For a coil having a span of 2/3 of pole pitch, the coil span factor is
A0.8
B0.866
C0.786
D0.966
#6📜 EE Pre-Board March 2015📘 PowerhouseEasy
A winding is short pitched by 60 degrees electrical. Its pitch factor is:
A0.5
B0.707
C0.966
D0.866
#7📜 EE Pre-Board March 2016📘 PowerhouseEasy
In a 10-pole synchronous machine, 20 electrical degrees are equivalent to how many mechanical degrees?
A2
B8
C4
D10
#8📜 EE Pre-Board March 2016📘 PowerhouseEasy
Calculate the average voltage generated in a six-turn full-pitch coil of a 25-cycle alternator if the flux per pole is \(7.2 \times 10^{5}\) maxwells.
A7.4 V
B8.64 V
C1.08 V
D4.32 V
#9📜 EE Pre-Board August 2017📘 PowerhouseEasy
A 500 kVA alternator operates at 80% of full load with an efficiency of 92 percent. If the load power factor is 0.8, calculate the total loss.
A27.83 kW
B32.0 kW
C34.78 kW
D25.6 kW
#10📜 EE Pre-Board August 2017📘 PowerhouseEasy
A three-phase, wye-connected, 6.25 kVA, 220-volt synchronous generator has a reactance of 8.4 ohms per phase. Using the rated kVA and voltage as base values, determine the per unit reactance.
A0.627 pu
B0.362 pu
C1.085 pu
D1.879 pu
#11📜 EE Pre-Board August 2017📘 PowerhouseEasy
A two-pole alternator is running at 1,500 rpm. What is the angular velocity?
A314.2 rad/s
B78.5 rad/s
C157.1 rad/s
D25 rad/s
#12📜 EE Pre-Board March 2018📘 PowerhouseEasy
Calculate the effective voltage in one phase of an alternator, given the following particulars: f = 60 cps; turns per phase N = 240; flux per pole = \(2.08 \times 10^{6}\) maxwells.
A1,330v
B2,304v
C1,225v
D2,122v
#13📜 EE Pre-Board March 2018📘 PowerhouseEasy
For coil having a span of 2/3 of pole pitch, the coil span factor is
A0.8
B0.866
C0.786
D0.966
#14📜 EE Pre-Board August 2018📘 PowerhouseEasy
In a 6-pole alternator how many mechanical degrees is the equivalent of 180 electrical degrees?
A60
B30
C120
D90
#15📜 EE Pre-Board August 2018📘 PowerhouseEasy
The field system of a 50 Hz alternator has a sinusoidal flux per pole of 0.1 Wb. Calculate the emf generated in one turn which spans two-thirds of a pole pitch.