A central generating station has an annual factor report as follows: Plant capacity factor = 50% Load factor = 60% Use factor = 45% Reserved = 10,500 kW Determine the rated capacity of the station.
A63,000 kW
B60,000 kW
C65,000 kW
D70,000 kW
#42📜 EE Board October 1990📘 1001 RojasEasy
A 55,000 kW thermal plant of National Power Corporation delivers an annual output of 238,000,000 kW-hr with a peak load of 44 MW. What is the capacity factor?
A49.4%
B42.4%
C48.2%
D44.6%
#43📘 1001 RojasMedium
A thermal power plant has two generating sets rated 600 kW and 800 kW respectively being operated at rated capacity. The total coal consumption is 680 kg per hour. If the coal has a heating value of 20,000 joules per gram, what fraction of heat produced from the coal is converted into useful electrical energy?
A37.06%
B40.20%
C33.67%
D38.28%
#44📜 EE Board October 1998📘 1001 RojasEasy
The metering of a power customer was read and gave the following data. kW-hr = 200,000 kVAR-hr = 180,000 Maximum demand = 380 kW Billing days = 30 What is the load factor?
A68%
B73%
C80%
D62%
#45📜 EE Pre-Board August 2012📘 PowerhouseEasy
What is the annual capacity factor of the plant if the annual energy produced in a 150 MW power plant is \(500 \times 10^{6}\) kWhr?
A56.785%
B34.44%
C44.04%
D38.05%
#46📜 EE Pre-Board August 2012📘 PowerhouseMedium
The tailwater and the headwater of a hydro-electric power plant are 150 m and 200 m, respectively. What is the water power if the flow is 15 m³/sec and a head loss of 10% of the gross head?
A4,621.56 kW
B7,621.65 kW
C5,621.76 kW
D6,621.75 kW
#47📜 EE Pre-Board August 2012📘 PowerhouseEasy
What is the total energy generated by a station in kWhr in a year if its maximum demand and annual load factor is 150 kW and 45%, respectively?
A513,900 kWhr
B531,900 kWhr
C593,100 kWhr
D591,300 kWhr
#48📜 EE Pre-Board March 2013📘 PowerhouseMedium
A three-phase motor driven pump at 1,800 rpm is discharging 500 gpm of water at a head of 25 meters. The pump efficiency is 75%. Determine the horsepower of the motor.
A15
B12
C14
D10
#49📜 EE Pre-Board March 2013📘 PowerhouseEasy
The average weekly energy generated by a thermal plant is \(7 \times 10^{6}\) kWhr. The peak load of the plant is 75,000 kW during the week. If the plant has an installed capacity of 100 MW, solve for the load factor of the plant.
A48.92%
B56.34%
C50.44%
D55.55%
#50📜 EE Pre-Board March 2013📘 PowerhouseMedium
A certain amount of fuel can produce 10 quads of energy. In how many days will the fuel be totally consumed if it is used to satisfy a demand of \(10^{13}\) BTU/day at a power plant with an overall efficiency of 20 percent?
A190
B205
C195
D200
#51📜 EE Pre-Board March 2013📘 PowerhouseMedium
A 100 MW power station delivers 100 MW for 2 hours, 50 MW for 8 hours and is shut down for the rest of each day. It is also shut down for maintenance for 60 days each year. Calculate its annual load factor.
A19%
B21%
C23%
D25%
#52📜 EE Pre-Board August 2013📘 PowerhouseMedium
Estimate the average power output of a wind turbine having a blade diameter of 10.7 m if the wind velocity ranges from 10 to 30 miles per hour.
A40.2kW
B42.2kW
C44.2kW
D46.2kW
#53📜 EE Pre-Board August 2013📘 PowerhouseHard
A certain power plant has a reserve capacity of 10 MW above the peak load. The annual factors are load factor = 59%, capacity factor = 41% and use factor = 46%. Determine the hours per year not in service.
A952 hours
B965 hours
C924 hours
D937 hours
#54📜 EE Pre-Board August 2013📘 PowerhouseMedium
A power plant consumes 3,600 tons of coal per day. If the coal has an average energy content of 10,000 BTU/lb, what is the plant's power output? Assume an overall efficiency of 15%.
A132 MW
B130 MW
C128 MW
D126 MW
#55📜 EE Pre-Board August 2013📘 PowerhouseMedium
A 100 MW hydroelectric station is supplying full load for 10 hrs in a day . Calculate the volume of water which has been used. Assume effective head of the water as 200 m and the overall efficiency of the station as 80%. Assume 1 m³ of water = 1,000 kg.
A2,232,435 m³
B2,345,456 m³
C2,293,560 m³
D2,371,402 m³
#56📜 EE Pre-Board August 2013📘 PowerhouseMedium
A power plant has an overall efficiency of 30%. If this plant consumes 4,200 kilograms of coal per hour, estimate the total electric energy produced in one day. Assume the calorific value of the coal is 5,000 kcal per kilogram.
A183 MWHR
B168 MWHR
C176 MWHR
D155 MWHR
#57📜 EE Pre-Board August 2013📘 PowerhouseMedium
A certain amount of fuel can produce 10 quads of energy. In how many days will the fuel be totally consumed if it is used to satisfy a demand of \(10^{13}\) BTU/day at a power plant with an overall efficiency of 20 percent?
A170
B180
C190
D200
#58📜 EE Pre-Board March 2014📘 PowerhouseMedium
What is the overall efficiency of the turbine if the power developed is 12 MW at a head of 150 meters and the nozzle discharges 10 cubic meters each second?
A70.65%
B78.99%
C81.55%
D89.23%
#59📜 EE Pre-Board March 2014📘 PowerhouseEasy
An industrial plant has an aggregate load of 100 kW. The demand factor is 60%. The average total energy consumption of the plant in one year is 186 MWHR. What is the yearly load factor of the plant?
A32.45%
B42.25%
C38.67%
D35.39%
#60📜 EE Pre-Board March 2014📘 PowerhouseMedium
A three-phase motor driven pump at 1,800 rpm is discharging 500 gpm of water at a head of 25 meters. The pump efficiency is 75%. Determine the HP of the motor.