Aan air-tight metal drum fixed at the top of the tank
Bdrum placed at the bottom of the tank
Coverload protection
Dnone of these
#62📜 EE Pre-Board March 2017📘 PowerhouseEasy
A transformer has negligible resistance and a p.u. reactance of 0.1. What is its voltage regulation on full load with a leading p.f. angle of 30°?
A-10%
B10%
C5%
D-5%
#63📜 EE Pre-Board March 2017📘 PowerhouseEasy
A transformer breathes in when
Aload on it increases
Bload on it decreases
Cload remains constant
Dnone of these
#64📜 EE Pre-Board August 2017📘 PowerhouseEasy
The output current corresponding to maximum efficiency for a transformer having a core loss of 100 watts and an equivalent resistance referred to the secondary of 0.25 Ω is ________ amperes.
A10
B20
C25
D40
#65📜 EE Pre-Board August 2017📘 PowerhouseEasy
If the copper loss of a transformer at 7/8 of full load is 4,900 W, what is its full-load copper loss?
A4,288 W
B6,400 W
C5,600 W
D3,752 W
#66📜 EE Pre-Board August 2017📘 PowerhouseEasy
Ideal transformer assumptions do not include
Azero winding resistance
Binfinite core permeability
Cno leakage flux
Da finite magnetizing current
#67📜 EE Pre-Board March 2018📘 PowerhouseEasy
Its primary purpose is to provide a ground source.
Azig-zag transformer
Bsectionalizer
Csurge arrester
Dtertiary transformer
#68📜 EE Pre-Board March 2018📘 PowerhouseEasy
Two single-phase, 25-kVA transformers are connected in an open-delta bank. Determine the maximum kW the bank can supply without overloading at 0.8 p.f. lagging.
A43.3
B34.64
C40
D50
#69📜 EE Pre-Board March 2018📘 PowerhouseEasy
Three 1:1 transformer units connected Δ/Y supply a 3-phase load from a 400 volt, 3-phase source. What is the line voltage on the load side?
A2,000v
B3,464v
C693v
D1,200v
#70📜 EE Pre-Board March 2018📘 PowerhouseEasy
The impedance of a 69 kV transformer is 14.28 Ω when referred to the primary. The transformer is a 10-MVA unit. What is the percent impedance of the transformer?
A4
B6.2
C3
D4.5
#71📜 EE Pre-Board August 2018📘 PowerhouseEasy
In transformers, the
Ahigh tension winding is used near the core
Bhigh tension winding is used away from the core
Clow tension winding is used near the core
Dlow tension winding is used away from the core
#72📜 EE Pre-Board August 2018📘 PowerhouseEasy
The overload kVA of each transformer of an open-delta bank is 11.56 kVA. If each transformer is rated 37.5 kVA, what is the kVA of the balanced 3Φ load?
A70
B80
C85
D90
#73📜 EE Pre-Board August 2018📘 PowerhouseEasy
A 7.5 MVA, 69/13.8 kV, 3-phase transformer has 8% impedance. What is the per unit impedance on a 10 MVA base?
A0.24
B0.106
C0.06
D0.096
#74📜 EE Pre-Board August 2018📘 PowerhouseEasy
Open circuit test on transformer is conducted to determine
Ahysteresis loss
Bcopper loss
Ccore loss
Deddy current loss
#75📜 EE Pre-Board August 2018📘 PowerhouseEasy
What is the maximum flux in mWb of a transformer with 200 primary turns when connected to a 60 Hz, 200 V supply?
A10.35
B6.25
C50.5
D3.75
#76📜 EE Pre-Board August 2018📘 PowerhouseEasy
A 75 KVA, 13,200/240, 60Hz, single-phase transformer has 1% resistance and 3% reactance. Find the copper loss of the transformer at 3/4 of full-load and unity power factor.
A155 W
B422 W
C368 W
D508 W
#77📘 EE Pocket Reviewer RojasEasy
Which of the following is the reason why the core of a transformer is heating up when the primary windings is connected to a supply voltage?
AReluctance of the core
BPermeability of the core
CHysteresis loss
DFerromagnetism
#78📘 EE Pocket Reviewer RojasEasy
A transformer will work on what type of voltage?
Adc only
Bac only
CBoth dc and ac
DAny kind of supply voltage
#79📘 EE Pocket Reviewer RojasEasy
For successful parallel operation of two single phase transformers, which one is the most essential condition required?